20T210 MODbus to HARTT210OEM module to be built into an MODbus based instrument in order to obtain the ability to communicate on HARTtrue0.000.0Built-in MODbus to HART./d2Y-18UlNO38pBp7t0B-hdtUZWSppxL6vToxUUW5mLtFcW89ExO74CT-tRJ6syJ1KWG.ips./T210+MODbus+to+HART.9SVTFlI56n_d2Z-0ow_j1X9f3TP9D6CJ1KWH.ipsT004.jpgT004Riktekst på Produktrich_text

General description

  • HART slave OEM module
  • Provides HART ability to MODbus transmitters
  • Communication options are RS485, RS232 or CMOS.
  • Connects to the line as a handheld communicator
  • T210 supports Universal and a selected set of Common Practice HART commands.
  • T210 supports Device Specific commands on demand.
  • T210 is compliant with the HART 5.8 standard.
  • T210 may be connected in HART multidrop configuration.
  • T210 supports HART burst mode communication
  • Small dimensions, 50 mm by 50 mm
  • Flash programmable

T210 is an OEM board designed for integration in 4-20 mA instruments with a MODbus transmitter. It allows upgrade of 4-20mA instruments to HART. It supports RS 232, RS 485 or a CMOS UART output.

T210 communicates on a serial line supporting the MODbus protocol. It reads a Primary Variable (PV) from the instrument. Calibration and parameter set-up capabilities require additional programming. Fint takes on to adapt the T210 to meet user specific requirements.  

T210 does not control the loop-current. The main instrument is supposed to do that. T210 connects capacitively to the loop. If the loop-current must be controlled in order to do loop testing or 4-20 mA trimming through a HART command, this can be achieved by adding the required support on the internal communication line between the T210 and the instrument.

T210 supports HART Universal Commands. If required, it may support Common Practice and Device Specific Commands. 

 

T210 application possibilities:

  •     Gas detectors
  •     Analysers
  •     Positioners
  •     Any smart instrument with 4-20mA out and with a MODbus protocol.

 

T210 specifications:

 

  • Mechanical size                               50 mm * 50 mm
  • Mounting                                         four 3 mm screws
  • Operating temperature range         -40 C to + 85 C
  • Input supply voltage range              6-30 Vdc
  • Line over voltage protection            50V
  • The HART Universal and Common Practice commands

 

HART Commands included:

 

  • All Universal Commands
  • Read variables
  • Read and write TAG name
  • Read range values and sensor limits
  • Read and write user massages and date
  • Common Practice commands required for
  • Selection of engineering units
  • Burst mode control

Device Specific Commands are included for factory set-up. To operate on these commands the user needs the HART Master program SW01. There are commands for setting addresses, serial numbers and sensor limits.

 The Starterkit ST21 contains the required tools for T210  

 


 

 

 

 

 


 