12T410 MODbus to PROFIbus PAT410The T410 is a built-in module for interfacing MODbus transmitters to a PROFIbus PA network.true0.000.0PROFI Built-in, serial./d2Y-18UlNO38pBp7t0B-hdtUZWSppxL6vToxUUW5mLtFcW89ExO74CT-tRJ6syJ1IYK.ips./T410+MODbus+to+PROFIbus+PA.9SVTFlI56n_d2Z-0ow_j1X9f3TP9D6CJ1IYL.ipslitekort3small.jpglitekort3small.jpgRiktekst på Produktrich_text

Description

T410 includes a MODbus master  in order to communicate with a MODbus instrument. The module reads the variables from the instrument and converts this to a dynamic variable on PA. Four AI Function Blocks are supported. The location of the MODbus registers and data type of the MODbus variable can be configured.  Other Function blocks can be added on request.


Applications

The T410 is intended to be integrated into MODbus instruments that shall be upgraded to interface to PROFIbus PA

 

Power options 

The following options are available for powering and galvanic isolation:

  1. The T410 comes with Galvanic isolation for instruments that are separately powered
  2. Power supply for the instrument (3.3Vdc).

 

Option 2  is only possible for low power consuming devices. The electrical interface should be CMOS.

Interface options

The following physical interfaces are supported.

  1. CMOS UART
  2. RS 232
  3. RS 485  
PA functionality supported:
  • Alarms
  • Low pass filtering
  • Unit conversion
  • Range
  • User calibration
  • Diagnostic information
Mechanical descriptionRound card - 65 mm in diamterOperation Temperature Range-40 °C - +85 °CElectrical SpecificationCurent draw 14 mA./9SVTFlI56n_d2Z-0ow_j1X9f3TP9DYyJ1IYy.ips21T400 HART to PROFIbus PAT400Built-in module for interfacing HART transmitters to a PROFIbus PA networks.true0.000.0PROFI Built-in, serial./d2Y-18UlNO38pBp7t0B-hdtUZWSppxL6vToxUUW5mLtFcW89ExO74CT-tRJ6syJ1KXH.ips./T400+HART+to+PROFIbus+PA.9SVTFlI56n_d2Z-0ow_j1X9f3TP9D6CJ1KXI.ipslitekort3small.jpglitekort3small.jpgRiktekst på Produktrich_text
Description

T400 includes a HART master  in order to communicate with a HART instrument. The module reads the Primary Variable (PV) from the instrument and converts this to a dynamic variable on PA. Four AI Function Blocks are supported. Other Function blocks can be added on request. The device has LAS (Master functionality).


Applications

The T400 is intended for HART instruments that shall be upgraded to interface to FOUNDATION fieldbus

 

Power options 

The following options are available for powering and galvanic isolation:

  1. The T400 comes with Galvanic isolation for instruments that are separately powered
  2. Power supply for the instrument (3.3Vdc) -  the HART physical layer is not applied.

 

Option 2  is only possible for low power consuming devices. The electrical interface should be CMOS.

PA functionality supported:
  • Alarms
  • Low pass filtering
  • Unit conversion
  • Range
  • User calibration
  • Diagnostic information

 

 



 

 



 

Mechanical descriptionRound card - 65 mm in diamterOperation Temperature Range-40 - 85 °CElectrical SpecificationCurrent draw 14 mA./9SVTFlI56n_d2Z-0ow_j1X9f3TP9DYyJ1KXv.ips28T411 MODbus to PROFIbus DPT411The T411 is a built-in module for interfacing MODbus transmitters to a PROFIbus DP network.true0.000.0PROFI Built-in, serial./d2Y-18UlNO38pBp7t0B-hdtUZWSppxL6vToxUUW5mLtFcW89ExO74CT-tRJ6syJ1K49.ips./T411+MODbus+to+PROFIbus+DP.9SVTFlI56n_d2Z-0ow_j1X9f3TP9D6CJ1K4-.ipsT004.jpgT004Riktekst på Produktrich_text

Description

T411 includes a MODbus master  in order to communicate with a MODbus instrument. The module reads the variables from the instrument and converts this to a dynamic variable on DP. Four AI Function Blocks are supported. The location of the MODbus registers and data type of the MODbus variable can be configured.  Other Function blocks can be added on request.

 

T411 supports the DP V1 protocol and PA profile 3.01


Applications

The T411 is intended to be integrated into MODbus instruments that shall be upgraded to interface to PROFIbus DP

 

Interface options

The following physical interfaces are supported.

  1. CMOS UART
  2. RS 232
  3. RS 485  
PA functionality supported:
  • Alarms
  • Low pass filtering
  • Unit conversion
  • Range
  • User calibration
  • Diagnostic information
Mechanical descriptionRound card - 65 mm in diamterOperation Temperature Range-40 °C - +85 °CElectrical SpecificationCurent draw 14 mA./9SVTFlI56n_d2Z-0ow_j1X9f3TP9DYyJ1K4X.ips